Welcome To Maxon Biochemistry Analyzer

Semi Automated Clinical Chemistry Analyzer

Welcome To Maxon Biochemistry Analyzer

Robust and Reliable Diagnostics Solution

The Analyzer is a curious fusion of reliability and performance. Its versatility improves productivity of modern labs through its robust design, intuitive software and hassle free operation

FLEXIBLE

Programmed to analyse endpoint, fixed time and kinetic assays. Storage for 200 user programmable test methods and 10000 test results. Create upto 10 constomised test profiles.

ECONOMICAL

Low reagent consumption. High quality surface coating ensures long filter life. Extended lamp life

ROBUST

Low maintenance. Consistent and reliable results. Indian design and manufacturing

OPTIMISED OPTICAL DESIGN

High sensitivity measurements for kinetic and turbidimetric assays (RF, ASO, CRP, etc)

LIGHT SOURCE

Halogen Quartz tungsten lamp (6v, 10 Watt).
Lamp life saving mode (Programmable sleep interval). Unique Lamp life enhancing circuit

ASPIRATION

High precision peristatic pump. Non corrasive tubing ensures long life and accurate aspiration. Aspiration air gap and auto empty function after each sample run. Minimal chances of carry over.

DEDICATED ASSAYS

One Touch Access to Dedicated Assays. 48 direct access assays

GRAPHS

Printable real time graph. Real time graph is displayed on screen and can be printed.

EASY MAINTENANCE

Self-diagnosis and system health reporting are an integral part of CurioLab. Easily set photometer gain and perform pump calibration.

Anaylysis Mode

Absorbance

Kinetic with factor and linearity check

Immunoturbidimetry

End Point with factor, standard or multiple standards with or without reagent/sample blank

Bochromatic Mode

Fixed time with standard, factor or multiple starndards, with or without reagent blank

SOFTWARE FEATURE

The Software is designed to simplify daily laboratory routine. It’s simple and intuitive work flow enhances user efficiency and productivity.

INTUITIVE USER INTERFACE

Six informative screens control operations. Easy navigation through submenus. Requires minimal training

CALIBRATION

Factor, one-point, two-point and multi-point. Non linear multi point calibration. Up to 3 replicates per point. Up to 10 calibration points.

QUALITY CONTROL

Mean, SD, % CV and R calculated for each assay. Level-Jennings control chart. 3 levels per assay. Westgard Rules

ERROR DETECTION

Early detection and reporting of errors on screen. Saves time and avoids faulty test runs which saves reagents.